TY - BOOK AU - Scaddan,Brian TI - IET Wiring Regulations: Explained and Illustrated SN - 9780429882999 AV - TK3271 U1 - 621.319240941 PY - 2018/// CY - Milton PB - CRC Press LLC KW - Electric wiring-Insurance requirements KW - Electronic books N1 - Cover -- Half Title -- Title Page -- Copyright Page -- Table of Contents -- Preface -- Introduction -- Chapter 1: Fundamental Requirements for Safety -- IET Wiring Regulations (IET Regulations Part 1 and Chapter 13) -- The Health and Safety at Work Act 1974 -- The Electricity at Work Regulations 1989 -- The Building Regulations 2010 Part 'P' -- Chapter 2: Earthing -- Earth: What Is It, and Why and How Do We Connect to It? -- Earth Electrode Resistance -- Earthing in the IET Regulations (IET Regulations Chapter 4, Section 411) -- Earthing Systems (IET Regulations Definitions (Systems)) -- Earth Fault Loop Impedance -- Determining the Value of Total Loop Impedance -- Residual Current Devices -- Chapter 3: Protection -- What is Protection? -- Protection Against Electric Shock (IET Regulations Chapter 41) -- SELV or PELV -- Protection Against Overcurrent (IET Regulations Chapter 43 and Definitions) -- Protection Against Overvoltage (IET Regulations Section 443) -- Protection Against Undervoltage (IET Regulations Section 445) -- Chapter 4: Isolation Switching and Control -- Isolation and Switching (IET Regulations Chapters 46 and 53) -- Chapter 5: Circuit Design -- Design Procedure -- Design Current -- Nominal Setting of Protection -- Voltage Drop (IET Regulations 525 and Appendix 4) -- Shock Risk (IET Regulations Section 411) -- Thermal Constraints (IET Regulations Section 543) -- Example of Use of the Adiabatic Equation -- An Example of Circuit Design -- Assessment of General Characteristics -- Sizing the Main Tails -- Sizing the Kiln Circuit Cable -- Chapter 6: Inspection and Testing -- Testing Sequence (Part 6) -- Chapter 7: Special Locations IET Regulations Part 7 -- Introduction -- BS 7671 Section 701: Bathrooms, etc -- BS 7671 Section 702: Swimming Pools -- BS 7671 Section 703: Hot Air Saunas -- BS 7671 Section 704: Construction Sites; BS 7671 Section 705: Agricultural and Horticultural Locations -- BS 7671 Section 706: Conductive Locations with Restrictive Movement -- BS 7671 Section 708: Caravan and Camping Parks -- BS 7671 Section 709: Marinas -- BS 7671 Section 710: Medical Locations -- BS 7671 Section 711: Exhibitions, Shows and Stands -- BS 7671 Section 712: Solar Photovoltaic (PV) Supply Systems -- BS 7671 Section 714: Outdoor Lighting Installations -- BS 7671 Section 715: Extra Low Voltage Lighting Installations -- BS 7671 Section 717: Mobile or Transportable Units -- BS 7671 Section 721: Caravans and Motor Caravans -- BS 7671 Section 722: Electric Vehicle Charging Installations -- BS 7671 Section 729: Operating and Maintenance Gangways -- BS 7671 Section 730: Onshore Units of Electrical Connections for Inland Navigation Vessels -- BS 7671 Section 740: Amusement Devices, Fairgrounds, Circuses, etc -- BS 7671 Section 753: Floor and Ceiling Heating Systems -- Appendix A: 18th Edition: Examination Question Sample Paper -- Sample Multiple Choice Question Paper -- Appendix B: Answers to Multiple Choice Test -- Index N2 - This general guide to electrical installation focuses on common misconceptions in the application of the 18th edition of the IEE IET Wiring Regulations, such as earthing and bonding, circuit design and protection, and the increased use of RCDs. It covers the requirements for both City & Guilds and EAL courses UR - https://ebookcentral-proquest-com.mlisicats.remotexs.co/lib/ppks/detail.action?docID=5508478 ER -